1305 the helicopter arrives over the fire and drops the crew on a gravel bar 3/4 mile downstream of the fire. They hike from the LZ up-canyon to a dirt road that parallels the river and walk the road toward the right flank of the fire. The fire is burning both above and below the road. Their helicopter is directed to begin dropping water on right flank above the road.
A local Division Chief is dispatched to the fire to be IC and drives past the helitack crew to the right flank. He observes a slow backing fire and returns to the location of the helitack crew, who are still hiking. Talking with the helitack captain, he does not identify himself as IC, announce a strategy or specific tactics. He does state that he wants the crew to find a safe anchor point but the crew understands him to want them to “anchor this fire on the right flank, the road down to the river”.
1335 the crew arrives at the right flank on the road and looks for access to the river and safe access to the bottom of the fire.
ATGS and IC decide to continue to use the helicopter on the right flank above the road. The helitack captain hears this exchange on the radio.
ATGS receives a radio call about a spot fire and misses discussion about helitack crew working below the road. (In a post-incident interview, the ATGS will state that he thought the crew was above the road.)
After scouting down the right flank about 70 feet, it is decided to construct indirect fire line downhill for 250 - 300ft to the river burning out from the road as they go. Safety zones are identified as down to the river, up to the road or into the black. All crew members agree with the plan and inform their helicopter pilot.
An engine is assigned to support the helitack crew. The crew is not notified that the engine was assigned to support them and that it was close by.
1340 firefighters located about 30ft down the line from the road remark that the burn out is pulling in nicely. There is a “flutter” in the wind and the 3 firefighters closest to the road are told to grab backpack pumps just in case.
1345 a sudden wind shift causes the fire to flare- up, change direction, and overrun the crew. 30 seconds later one crew member is dead. No fire shelters are deployed.
(Photo credit: Cal Fire) |
During size-up, what fire behavior did the personnel observe? If you were at a fire in a similar setting, what local terrain features and other factors might lead you to distrust the fire behavior seen?
It is common for people to have communication problems. On an incident where these issues can
easily compromise anyone’s life safety, what are you going to do to minimize communication errors… as a Crew member? Crew boss? Pilot? IC?
Your crew has been dispatched to this fire. How will you handle the “Lookout” aspect of LCES? It is common to hear that “everyone on the crew is a lookout”. Discuss what each person must do to make this an effective alternative to the “traditional” lookout.
This fire had an Air Attack and a helicopter. Discuss if and how aerial resources can be used as additional lookouts and sources of information. What are some downfalls to using them in this role?
No comments:
Post a Comment